Carscop - CCTR-828-4G Configuration
This page documents the public configuration context for using the Carscop CCTR-828-4G tracker with Plaspy. It focuses on the practical server and SMS-based setup information that operators commonly use to point the device at Plaspy and enable telemetry uploads. Use this guide to understand the key server settings and the sample SMS commands provided by the device manufacturer.
Plaspy uses shared server settings across supported trackers and automatically detects the device protocol when the unit connects. Manufacturer-side setup steps can vary by firmware revision, hardware revision, installation type, and vendor tools, so confirm device-specific steps against Carscop documentation when in doubt. The CCTR-828-4G supports open GPRS configuration and SMS commands, which are commonly used to set APN, server, and basic behavior for integration with Plaspy.
Configuration Overview
The goal of the configuration process is to prepare the CCTR-828-4G to communicate reliably with Plaspy, validate connectivity, and make the device visible in the Plaspy platform. This involves setting the network APN, pointing the device to the Plaspy server endpoint and port, and enabling the tracker to remain online for reporting.
- Configure the device APN and optional APN credentials so the tracker can use the mobile data network for GPRS uploads.
- Set the tracker to report to the Plaspy server endpoint and port so Plaspy receives telemetry and location updates.
- Choose the transport protocol (UDP or TCP) if the device requires a transport selection and ensure the port matches Plaspy standard port settings.
- Validate connectivity and keepalive behavior so the tracker remains registered and visible in Plaspy.
- Use the provided SMS commands for devices that support SMS-based configuration to apply settings without disassembly.
Plaspy Server Settings
- Server domain d.plaspy.com
- Server IP 54.85.159.138
- Port 8888
- Transport support for UDP or TCP on port 8888
- Plaspy automatically detects the tracker protocol when the device connects
These values are the public Plaspy endpoint details used for pointing the CCTR-828-4G to Plaspy. Plaspy uses the same port for all supported devices and will detect the appropriate protocol automatically.
Typical Requirements Before Setup
- A functional SIM card with data enabled and, if required, SMS service for configuration commands.
- Access to the tracker's SMS configuration method or official manufacturer configuration tool.
- The device powered and reachable (vehicle power or an external power source) so it can receive SMS commands and establish GPRS.
- The APN, APN username, and APN password from your mobile operator if the SIM's APN is not automatic.
- Basic knowledge of the device password; the sample default password used in manufacturer commands is 123456.
- A way to verify device reports in Plaspy after configuration, such as an account with access to the platform or a partner console.
How This Tracker Connects to Plaspy
The CCTR-828-4G is configured to upload location and telemetry using GPRS over the cellular network. Once the device is pointed to Plaspy and the APN is set, the tracker will establish a connection to the shared Plaspy server endpoint and port to deliver real-time updates and event notifications.
- The tracker is configured to report to the shared Plaspy server endpoint and port as part of its GPRS server settings.
- Device telemetry and location updates are sent to d.plaspy.com or the Plaspy server IP at 54.85.159.138 on port 8888.
- Transport can be UDP or TCP depending on the device configuration; Plaspy listens on port 8888 and detects the protocol automatically.
- Plaspy receives and processes uploads for real-time visibility, event reporting, and history playback.
- Keepalive or online commands ensure the device remains reachable and continues reporting to Plaspy.
Common Configuration Workflow
- Access the official Carscop configuration method for your unit, typically SMS commands or the manufacturer configuration tool or app.
- Ensure the device has power and an active SIM with data and optional SMS capability.
- Enter the Plaspy server by specifying d.plaspy.com or the server IP 54.85.159.138 in the device server settings.
- Set the port to 8888, which is the standard port Plaspy uses for all devices.
- Choose UDP or TCP if the device requires selection of a transport protocol.
- Apply or save the configuration and, if the device requires it, restart the tracker to apply network settings.
- Validate that the device reports to Plaspy by checking device status and telemetry in your Plaspy account.
If the CCTR-828-4G supports SMS-based configuration (as shown below), sending the commands in the order shown will set the most common parameters for Plaspy integration.
Example Configuration Commands
The manufacturer provides SMS commands for configuration. The sample commands below use the device default password 123456. Preserve and replace placeholders where required.
- Restore factory settings (optional initial step)
RESET*123456
- Set the time zone to UTC+0
TIMEZONE*123456*+00
- Set the operator APN (replace [apn] with your mobile operator APN)
APN*123456*[apn]
- Set the APN username and password if required (replace [apnu] and [apnp] with your APN credentials)
USERNAME*123456*[apnu]*[apnp]
- Set the GPRS server by IP and port to the Plaspy server
IP*123456*54.85.159.138,8888
Note: If the device accepts a domain name instead of an IP, you can use d.plaspy.com in place of the IP.
- Enable keep online behavior to keep the tracker connected
KEEPONLINE*123456
Placeholders explained:
- [apn] — operator APN string required for data connection.
- [apnu] — optional APN username.
- [apnp] — optional APN password.
Use these SMS commands in the order shown when performing initial setup. The RESET command is optional and typically used only when returning the device to factory defaults before reconfiguration.
Configuration Notes
- SMS-based configuration is supported for the CCTR-828-4G and is commonly used to set APN, server IP, and keepalive behavior.
- Firmware and hardware revisions can change command syntax or available features; confirm the exact SMS commands against the device manual for your unit.
- Choose UDP or TCP according to installer preference or device capability; Plaspy listens on port 8888 and detects the protocol automatically.
- Plaspy uses the same port for all supported devices, which simplifies configuration and fleet-wide deployment.
- If your unit supports using a domain name for server settings, d.plaspy.com can be used instead of the numeric IP address.
Why Use Plaspy with This Configuration
Using the Carscop CCTR-828-4G with Plaspy gives operators centralized visibility into vehicle location, event reporting, and history playback while using a straightforward, proven configuration flow. Pointing the device to the Plaspy server and configuring APN and keepalive settings provides a reliable channel for real-time telemetry and operational monitoring across mixed fleets.
To learn more about Plaspy and platform capabilities visit https://www.plaspy.com. For the most current device-specific setup steps, firmware notes, and manufacturer documentation verify details at the Carscop website http://www.carscop.com/ as manufacturer specifications and setup methods can change over time.
Tracker Configuration
Need a platform for this tracker setup
Plaspy helps you connect compatible trackers, receive device data, and centralize monitoring from one GPS tracking platform.