OKB Tehnoavtomatika - MPU-01 Configuration
This page provides public configuration context for using the OKB Tehnoavtomatika MPU-01 tracker with Plaspy. It summarizes the practical server settings and workflow needed to make the MPU-01 report to the Plaspy platform and to confirm visibility in the Plaspy interface.
Plaspy uses shared server settings across supported devices and automatically detects the tracker protocol, but the exact manufacturer-side setup steps for the MPU-01 can vary depending on firmware version, hardware revision, installation type, and vendor tools. The MPU-01 description above — including its high sensitivity GPS receiver, GSM SMS channel support, and compact design — is the basis for the guidance below.
Configuration Overview
The goal of configuring an MPU-01 for Plaspy is to prepare the device to communicate reliably with the Plaspy server, validate connectivity over the chosen transport, and enable the device to appear and report events inside Plaspy. The MPU-01 supports SMS messaging via GSM and has flexible small form factor options, which installers should consider during setup.
- Point the device to the Plaspy server domain or IP so telemetry is sent to the correct endpoint.
- Select the transport protocol supported by the device and Plaspy, UDP or TCP, and set the shared port.
- Apply and save settings using the official OKB Tehnoavtomatika configuration method or SMS commands if supported.
- Reboot or restart the device if required to activate new server settings.
- Verify the device appears in Plaspy and is sending location updates and status reports.
Plaspy Server Settings
- Server domain d.plaspy.com
- Server IP 54.85.159.138
- Port 8888
- Transport support for UDP or TCP on port 8888 depending on device capability
- Plaspy automatically detects the tracker protocol so the same port is used for all supported devices
Typical Requirements Before Setup
- A powered MPU-01 unit with required battery or vehicle power connection and any installation accessories in place.
- Access to the official OKB Tehnoavtomatika configuration method or approved vendor tool for MPU-01 setup.
- A valid GSM SIM and network coverage if SMS or cellular telemetry is used, as MPU-01 supports SMS via GSM channels.
- Knowledge of whether the MPU-01 unit accepts configuration via SMS, serial console, or dedicated configuration software.
- Access to Plaspy account details for device verification after configuration.
- A basic test plan to confirm connectivity and reporting once server settings are applied.
How This Tracker Connects to Plaspy
The MPU-01 is configured to send its location and status messages to Plaspy by directing its server endpoint and transport settings to the shared Plaspy address and port. Plaspy receives the incoming data on the common port and identifies the tracker protocol automatically so devices become visible without device-specific ports.
- The tracker is pointed to the Plaspy server domain or IP and port so telemetry flows into Plaspy.
- Data can be sent over UDP or TCP depending on the selected transport in the device configuration.
- Plaspy listens on port 8888 for all devices and performs automatic protocol detection.
- Once connected, the device will report periodic position updates and status events to Plaspy.
- Visibility in Plaspy confirms successful communication and allows monitoring and alerts.
Common Configuration Workflow
- Access the official OKB Tehnoavtomatika configuration method or software for the MPU-01 as provided by the manufacturer or your installer.
- In the server settings, enter the Plaspy server domain d.plaspy.com or the server IP 54.85.159.138.
- Set the server port to 8888 as Plaspy uses the same port for all devices.
- Choose UDP or TCP if the MPU-01 requires you to select a transport protocol.
- Apply or save the configuration changes in the device configuration tool or via SMS commands if supported.
- Restart or power cycle the MPU-01 if the manufacturer instructions require a reboot to apply changes.
- Validate that the device reports to Plaspy by checking device visibility and recent messages in your Plaspy account.
Example Configuration Commands
No public modelConfiguration commands were provided for the MPU-01 in this document. The exact configuration commands and syntax can vary by firmware and the manufacturer tool you use. For MPU-01 units that support SMS configuration, typical workflows involve sending SMS configuration strings or using the vendor configuration utility; for units configured via a software tool, enter the Plaspy server settings directly in the server or network pane.
If you have manufacturer supplied command examples or SMS templates from OKB Tehnoavtomatika, apply them in the order recommended by the vendor and replace any placeholders such as APN values with your actual network information.
Configuration Notes
- Firmware and hardware revisions for MPU-01 can change available configuration options; always confirm version specific instructions from the manufacturer.
- Choose UDP or TCP based on your installation needs and any guidance from the installer or network operator; both transports are supported by Plaspy on port 8888.
- SMS based configuration may be available for initial setup or remote changes if the MPU-01 supports it; consult the device manual for SMS command syntax.
- Plaspy uses a single shared port and automatic protocol detection so device-side configuration focuses on endpoint and transport selection rather than custom ports.
- Keep a record of the original device settings before changes so you can revert if needed.
Why Use Plaspy with This Configuration
Configuring the OKB Tehnoavtomatika MPU-01 to report to Plaspy provides a straightforward way to bring device telemetry and location reporting into a single fleet or asset visibility platform. Using the shared Plaspy server settings and automatic protocol detection reduces per-device complexity and helps teams deploy multiple devices faster.
To learn more about Plaspy and platform capabilities visit https://www.plaspy.com. Device specific configuration methods, firmware behavior, and manufacturer details can change over time so verify the latest setup instructions with OKB Tehnoavtomatika at http://www.okb-ta.ru/ before finalizing installations.
Tracker Configuration
Need a platform for this tracker setup
Plaspy helps you connect compatible trackers, receive device data, and centralize monitoring from one GPS tracking platform.