Skip to main content

YulongDa - H02 Configuration

This page documents the public configuration context for using the YulongDa H02 tracker with Plaspy. It explains the shared Plaspy server settings required to route device data into the platform and shows practical, publicly available SMS commands and configuration steps used by many installers and integrators.

Plaspy uses the same server and port settings across supported devices and automatically detects the tracker protocol when the device connects. Exact manufacturer side steps can vary by firmware version, hardware revision, installation type, or vendor configuration tools, so this page focuses on the public, practical settings and the SMS commands included in the available model configuration example.

Configuration Overview

The goal of configuring the YulongDa H02 for Plaspy is to prepare the device to send location and status data reliably to the shared Plaspy endpoint so the unit appears and updates correctly in the platform. The public commands below and the server settings let you set the operator APN, point the device at the Plaspy endpoint, and adjust basic reporting intervals.

  • Configure the operator APN so the device can attach to the mobile data network and reach Plaspy.
  • Set the GPRS server address so data is delivered to Plaspy at d.plaspy.com or the equivalent IP.
  • Adjust position reporting intervals for moving and stopped states to match monitoring needs.
  • Validate connectivity from the device to Plaspy and confirm the device appears in the platform.
  • Ensure the device uses UDP or TCP on the shared Plaspy port as required.

Plaspy Server Settings

  • Server domain d.plaspy.com
  • Server IP 54.85.159.138
  • Port 8888
  • Transport support for UDP or TCP on port 8888
  • Plaspy automatically detects the tracker protocol when the device connects

These values are the public Plaspy endpoint settings to use when configuring the H02.

Typical Requirements Before Setup

  • A powered and accessible YulongDa H02 unit with a working SIM card and active data plan if using GPRS data delivery. The H02 supports GPRS or SMS based configuration paths as shown in the example commands.
  • Knowledge of the SIM operator APN and any required username or password for data access.
  • Access to the manufacturer supported configuration method such as SMS commands or the vendor configuration tool.
  • The device default password if required by the command set; the example commands assume the initial password 000000.
  • Mobile network coverage and GPRS connectivity at the installation location.
  • A way to receive or view the device on Plaspy after applying settings to validate that reporting is active.

How This Tracker Connects to Plaspy

The YulongDa H02 transmits recorded position data to the Plaspy platform using cellular data or SMS depending on the modem and configuration. When configured to use GPRS, the device opens a connection to the Plaspy server endpoint and sends telemetry on the shared port.

  • The device is pointed to the Plaspy server domain or IP so outgoing data is routed to Plaspy.
  • Data is sent over UDP or TCP to port 8888 as configured on the device.
  • Plaspy automatically detects the incoming tracker protocol and processes the device messages.
  • Regular position updates and state changes are transmitted so the unit becomes visible in the Plaspy interface.
  • Reporting intervals can be adjusted so moving and stopped updates match your monitoring needs.

Common Configuration Workflow

  1. Access the official YulongDa configuration method for H02 such as the manufacturer SMS command set or configuration software.
  2. Enter the Plaspy server domain d.plaspy.com or the Plaspy server IP 54.85.159.138 in the server or IP field.
  3. Set the destination port to 8888.
  4. Choose UDP or TCP if the device requires a transport selection; Plaspy supports both on the same port.
  5. Set the operator APN and any APN username or password required by the SIM using the appropriate command or tool.
  6. Apply or save the configuration and restart the device if required by the manufacturer instructions.
  7. Validate that the device reports to Plaspy by checking device presence and recent position updates in the Plaspy platform.

If you are using the provided SMS commands, follow the order and defaults described below to set APN, server, and reporting intervals.

Example Configuration Commands

The following commands are extracted from the public model configuration example for H02. These use SMS messages sent from a control phone to the device. The examples assume the device initial password 000000 which may be the factory default. Keep placeholders as shown.

  • Set the operator APN. If the APN requires a username or password send the variant that includes [apnu] and [apnp].
*APN#000000#[apn]#

Optional variant with APN username and password:

*APN#000000#[apn]#[apnu]#[apnp]#

Note: Replace [apn] with your mobile operator APN string. Replace [apnu] and [apnp] with APN username and APN password if your operator requires them. If no username or password is needed, use the shorter command.

  • Set the GPRS server to Plaspy using the Plaspy server IP and port:
*IP#000000#54.85.159.138#8888#

This command points the device at Plaspy. You can also use d.plaspy.com in manufacturer tools or fields that accept domain names.

  • Set the update interval while moving to 60 seconds:
XT60
  • Set the update interval while stopped to 60 seconds:
NXT60

Preserve command order when following manufacturer guidance. Some devices accept domain names in place of the IP address but the IP shown above is the public Plaspy endpoint used in the example. If your device requires explicit transport selection for UDP or TCP, use the device tool or SMS command documented by YulongDa to choose the preferred transport; Plaspy supports both on port 8888.

Configuration Notes

  • The example commands use SMS based configuration which is commonly supported by YulongDa devices, but some setups use PC software or over the air tools depending on firmware and model revision.
  • Default device passwords vary by production and region; the example commands assume 000000 as an initial password. Confirm the actual password with the device label or manufacturer documentation.
  • Firmware differences can change command syntax, available commands, or required steps. Always confirm syntax against the current YulongDa documentation for H02.
  • Choose UDP or TCP on the device only if the device requires an explicit transport selection. Plaspy will accept either protocol on the shared port 8888.
  • Verify APN, username, and password values with the mobile operator before sending commands. Incorrect APN settings will prevent GPRS connectivity.

Why Use Plaspy with This Configuration

Using the YulongDa H02 with Plaspy provides a straightforward way to centralize location and status reporting for vehicles and other assets. With the shared Plaspy server endpoint and automatic protocol detection, many H02 units can be configured quickly to report into a single platform for monitoring, reporting, and operational oversight.

To learn more about Plaspy and how it works with supported trackers visit https://www.plaspy.com. For the latest device specific commands, firmware notes, and configuration guidance for the YulongDa H02 confirm details on the manufacturer website http://www.yulongdatechnology.com as setup steps and firmware behavior can change over time.

Tracker Configuration

Need a platform for this tracker setup

Plaspy helps you connect compatible trackers, receive device data, and centralize monitoring from one GPS tracking platform.